start stop button RENAULT TWINGO 2009 2.G Engine And Peripherals Passenger Compartment Connection Unit OBD Workshop Manual

Page 76 of 179

87B-76
MR-413-X44-87B000$480.mif
V5
UCH
Vdiag No.: 44PASSENGER COMPARTMENT CONNECTION UNIT
Fault finding - Conformity check87B
FUNCTION: AIR CONDITIONING
SUB-FUNCTION: COLD LOOP
NOTESOnly carry out this conformity check after a complete check with the diagnostic tool
(fault reading and configuration checks).
Application condition: engine stopped, + after ignition feed present.
FunctionParameter or Status
Checked or ActionDisplay and notes Fault finding
Cold loopPR002:External
temperature˚CIn the event of a fault, refer to the
interpretation of parameter
PR002.
ET142:Engine operating
phaseSTOPPED
STARTING
RUNNING
STALLEDIn the event of a fault, refer to the
interpretation of status ET142.
ET015:Passenger
compartment
blowerRUNNING
STOPPEDIn the event of a fault, refer to the
interpretation of status ET015.
ET030:Air conditioning
requestThis request is sent by the
UCH to the engine
management computer.
There are two possible
scenarios:
1
st scenario: vehicle equipped
with manual air conditioning.
The request is made by
pressing the air conditioning
button.
2
nd scenario: vehicle
equipped with climate control.
The request is made following
a user request or climate
control computer request.In the event of a fault, refer to the
interpretation of status ET030.
PR025:Engine speed0 rpmIn the event of a fault, run fault
finding on the multiplex network
(see 88B, Multiplex) then run
fault finding on the injection
system (see 13B, Diesel
injection or 17B, Petrol
injection).